Sunday, March 9, 2008

Biodegradability Test

“Compatibility of the ISO standard 10708 (biodegradability test method) with the ultimate biodegradability requirements imposed through Annex III of Regulation 648/2004 of Parliament and of the Council”

EUROPEAN COMMISSION
HEALTH & CONSUMER PROTECTION DIRECTORATE-GENERAL
Directorate C - Public Health and Risk Assessment
C7 - Risk assessment

Adopted by the SCHER
during the 3rd plenary of 28 January 2005

ISO standard 10708

1. BACKGROUND

Annex III of Regulation 648/2004 lists a set of OECD / ISO test methods aiming at providing International standardised methodologies to quantify the ultimate biodegradability of surfactants in aerobic conditions.

The international ISO 10708 standard, not included in Annex III of Regulation 648/2004, aims to determine the ultimate aerobic biodegradability of organic compounds in an aqueous medium. This test method is apparently similar to the “closed bottle test” (OECD 301 D).

The Scientific Committee on Toxicology, Ecotoxicology and the Environment (CSTEE) already examined a request addressing a similar issue (ultimate test methods on biodegradability currently listed in Annex III, Regulation 648/2004) and adopted an opinion on “a proposed ready biodegradability approach to update detergent legislation” at its 12th plenary meeting of 25 November 1999.

According to Industry, ISO standard 10708 method provides an equivalent level on reliability compared to the other OECD test methods addressing the ultimately biodegradability features of surfactants (Annex III of Regulation 648/2004).

2. TERMS OF REFERENCE
The Scientific Committee on Health and Environmental Risks (SCHER) is requested to address this issue and give an opinion whether
1) the methodology and
2) the pass criterion
of ISO 10708 provide an equivalent level of reliability and stringency to the international test methods set out in Annex III of the Regulation 648/2004.

3. OPINION
3.1. Methodology
The biodegradability test method ISO 10708 was developed to have a relatively inexpensive and simple method for the ultimate aerobic degradability of poorly soluble chemicals. It was called BODIS (BOD of insoluble chemicals) or two-phase Closed bottle test, the latter because BOD bottles and an oxygen electrode are used like in the “Closed-Bottle-Test (OECD 301 D)”. One third of the bottle (headspace) acts as an oxygen reservoir. Consequently, higher test substance concentrations than in the “Closed-Bottle-Test (OECD 301 D)” can be used, as the oxygen concentration in the (saturated) medium is no longer the limiting factor for degradation. Concentrations of up to 100 mg COD/l can be weighed directly into the test flasks. The method was included in an OECD ring-test (OECD, 1989) which will be discussed under section 3.2.

The procedure and technical requirements of the ISO 10708 test are relatively simple. Considering the test conditions, the method is congruent with most of the biodegradability methods included in Annex III of Regulation 648/2004 in terms of the test medium, inoculum type and concentration, test duration, etc.(Table 1).


Table 1 - Comparison of the ISO 10708 test conditions and those included in Annex III of the Regulation 648/2004


Considering the test design, it is equivalent to the ISO 14593, test which is the reference method in the Annex III of the Regulation 648/2004 except for the detection parameter. Eisentraeger et al. (202) presents a combined biodegradation test system where both parameters are measured, the test results for 15 samples (poorly soluble lubricants, ester oil or mineral oil) after 28 days of incubation demonstrated that results obtained for both parameters are in a comparable range.

Overall, the ISO 10708 test is comparable in terms of the methodology to the tests described in Annex III of the Regulation 648/2004; combining in its methodological design elements of the reference method ISO 14593 and of other methods described in OECD 301. The reasons for not including this test in the OECD guideline 301 does not seem to be related to scientific issues but are rather of a managerial nature. In this context OECD (1989) states “The Set I Two Phase Closed-Bottle test does not appear to offer any significant advantages over the existing respirometric tests, being labour and space intensive”.

3.2. Pass criterion
There are three main sources of information allowing a comparison of the biodegradation results obtained with the ISO 10708 to those acquired by other ready biodegradation methods.

Ritcherich et al. (1998) compared biodegradation data from the “Two- phase closed bottle test” (BODIS test) and the OECD 301D (Closed Bottle test). 54 poorly soluble compounds were compared. For 46 % of the substances the ISO 10708 biodegradation was significantly higher (i.e., data differed ≥10% relatively to each other) than that observed in the Closed Bottle test; 7% of the substances degraded better in the Closed Bottle test and 44 % gave comparable results (difference less than 10%). Taking the 60 % BOD/COD pass criterion, for 83% of the substances the same conclusion on ready biodegradability was obtained, whereas for the remaining 17 % only the ISO 10708 test indicated readily biodegradability.

The CESIO (European Committee of Organic Surfactants and their Intermediates) has provided biodegradation test (OECD 301 D/F tests and ISO-10708) results for a set of anionic, cationic and non-ionic surfactants, allowing a comparative evaluation. The information was supplied by CESIO (Appendix 2) in tabular form without additional information and, therefore, the SCHER cannot confirm the quality and validity of the data.

Figure 1 presents a comparison of both methods. In general a relatively good linear correlation between both methods is observed. On average, the degradation value obtained in the BODIS test tend to be higher than in the OECD methods (as suggested by the slope of the line); for three out of 24 surfactants the differences in biodegradability were larger than 20%.

Figure 1 - Comparison of ISO 10708 and OECD 301D/F using degradation data on surfactants provided by CESIO (2004).

Using the biodegradability pass criterion of the 60% BOD/COD, comparison of the biodegradability test data of 24 surfactants shows that 21 compounds (88%) reached the same evaluation (14 above and 7 below the pass level) whereas 3 compounds (12%) only passed the ISO-10708 test.

A calibration exercise of methods for determining ready biodegradability was performed by the OECD in 1988 and a final report on the evaluation of these results was issued in 1989. This report compared the biodegradability data obtained for 4 organic compounds applying different OECD ready biodegradability tests (301B, 301C, 301 D and 301F) and the ISO 10708 test.

The variability inter- and intra-assays observed in the inter-calibration exercise was high, as expected for these biological assays. The results obtained in the OECD intercalibration exercise must be considered for putting into context the comparison presented in Figure 1. Similar levels of discrepancy were observed among other tests included in Annex III of the Regulation 648/2004 and even among laboratories conducting the same tests (OECD, 1989).

From the evaluation of the above mentioned studies and considering the observed variability, the biodegradation results obtained with the ISO 10708 are consistent (i.e., results in a similar final evaluation) with those obtained with the OECD ready biodegradability methods.

4. CONCLUSION
Referring to the terms of reference, the SCHER concludes that:
the ISO 10708 test is comparable in terms of the methodology to the tests described in Annex III of the Regulation 648/2004, and the ISO 10708 provides an equivalent level of reliability and stringency to the international test methods set out in Annex III of the Regulation 648/2004.

5. LIST OF ABBREVIATIONS
BOD Biological Oxygen Demand
CBT Closed Bottle Test (OECD 301 D)
COD Chemical Oxygen Demand
DOC Dissolved Organic Carbon

6. REFERENCES
CESIO (2004) Appendix 2: Comparison of Biodegradability Test Data. CESIO Oct 2004.
Eisenträger A., Schmidt M., Murrenhoff H., Dott W. and Hahn S. (2002) Biodegradability testing of synthetic ester lubricants – Effects of additives and usage, Chemosphere 48, 89-96.

OECD (1989) Ring test of methods for determining ready biodegradability, Final report, Paris, 1989.

Richterich K., Berger H. and Steber J. (1998) The ‘two-phase closed bottle test’ a suitable method for the determination of ‘ready biodegradability’ of poorly soluble compounds. Chemosphere 37 (2) 319-326.

7. ACKNOWLEDGEMENTS
Members of the working group are acknowledged for their valuable contribution to this opinion. The members of the working group are:

Prof. M. T. Garcia Ramon (external expert) Dr. S. Hahn (external expert), Prof. C. Janssen, Prof. J. Tarazona (rapporteur).

Sunday, March 2, 2008

Graft polymerization of acrylonitrile onto starch-coated polyethylene film surfaces (**)

Journal of Applied Polymer Science
Volume 89, Issue 12, Pages 3323-3328
Received: 8 October 2002; Accepted: 17 December 2002
Published Online: 1 Jul 2003
George F. Fanta (a) (*) , Frederick C. Felker (b), John H. Salch (a)
(a) Plant Polymer Research, National Center for Agricultural Utilization Research, United States Department of Agriculture, 1815 North University Street, Peoria, Illinois 61604-3999
(b) Cereal Products and Food Science Research, National Center for Agricultural Utilization Research, United States Department of Agriculture, 1815 North University Street, Peoria, Illinois 61604-3999

(*)Correspondence to George F. Fanta, Plant Polymer Research, National Center for Agricultural Utilization Research, United States Department of Agriculture, 1815 North University Street, Peoria, Illinois 61604-3999. email: George F. Fanta (fantagf@ncaur.usda.gov)
(**)Mention of a trademark, proprietary product, or vendor does not constitute a guarantee or warranty of the product by the U.S. Department of Agriculture and does not imply its approval to the exclusion of other products or vendors that may also be suitable.

Keywords: starch • polyethylene • acrylonitrile • polyacrylonitrile • graft copolymer

Starch-coated polyethylene (PE) films were prepared by immersing PE in a hot, jet cooked solution of starch. They were allowed to react with acrylonitrile (AN) in the presence of ceric ammonium nitrate initiator, and the graft polymerization that occurred produced starch-g-polyacrylonitrile (PAN) coatings that contained about 25 wt % grafted PAN. The starch-g-PAN coatings tightly adhered to the PE film surfaces. When grafted starch coatings were wetted with water and the surfaces vigorously rubbed, less than 20% of the coating was removed. The fact that PAN-grafted coatings were not removed with boiling water provided further evidence for their strong adherence. When starch was removed from the coating by acid hydrolysis, the residual grafted PAN still remained adsorbed on the PE surface. Because the grafted coating was completely removed by treatment with refluxing 0.7N sodium hydroxide, there is apparently no chemical bonding between starch-g-PAN and PE. The dimensional changes associated with the evaporation of water from these PAN-grafted coatings caused the films to curl during drying. Because the final shape of these coated films depends upon the presence or absence of water in the surrounding environment, these films may be considered to be a type of stimulus-responsive polymer. Attempts to graft polymerize methyl methacrylate and methyl acrylate onto starch-coated PE surfaces, under conditions similar to those used with AN, were unsuccessful. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 89: 3323-3328, 2003

Radiation-induced grafting polymerization of MMA onto polybutadiene rubber latex

Jing Peng (a), Maolin Wang (a), Jinliang Qiao (b) and Genshuan Wei (a)
(a) Department of Applied Chemistry, College of Chemistry, Peking University, Beijing 100871, PR China
(b) SINOPEC Beijing Research Institute of Chemical Industry, Beijing 100013, PR China

Abstract
The grafting of methyl methacrylate (MMA) onto polybutadiene rubber latex by the direct radiation method was carried out. The effects of monomer concentration, absorbed dose and dose rate of gamma rays on the grafting yield were investigated. The graft copolymers were characterized by transmission electron microscopy (TEM), FTIR spectroscopy, and differential scanning calorimetry. TEM photographs revealed that the core–shell structures of latex particles are formed at low MMA content, and with the increasing of MMA content, the semi-IPN-like structure with core–shell could be developed due to the high gel fraction of polybutadiene (PBD) seed particles. In addition, infrared analysis confirmed that MMA could be grafted onto PBD molecular chains effectively under appropriate irradiation conditions. The interfacial adhesion between PBD rubber (core) and PMMA (shell) phases could be enhanced with the increase of MMA concentration.

The writer can be reach by email : gswei@pku.edu.cn